@@ -18,6 +18,13 @@ class PingTest(OERuntimeTestCase):
output = ''
count = 0
self.assertNotEqual(len(self.target.ip), 0, msg="No target IP address set")
+
+ # If the target IP is localhost (because user-space networking is being used),
+ # then there's no point in pinging it.
+ if self.target.ip.startswith("127.0.0.") or self.target.ip in ("localhost", "::1"):
+ print("runtime/ping: localhost detected, not pinging")
+ return
+
try:
while count < 5:
cmd = 'ping -c 1 %s' % self.target.ip
new file mode 100644
If SLIRP is being used instead of TAP for networking to the guest then the target IP will be localhost. There's no point in pinging localhost to see if the target is up but whilst you'd think it is harmless, in some containers ping doesn't actually have enough rights to work: ping: socktype: SOCK_RAW ping: socket: Operation not permitted ping: => missing cap_net_raw+p capability or setuid? Look at the target address and if it's localhost or 127.0.0.* return immediately. (Backport from OE-Core rev: a06ef43d2a50e16c32bd6edbdc7b32c3528687d5) Signed-off-by: Michael Haener <michael.haener@siemens.com> --- meta/lib/oeqa/runtime/cases/ping.py | 7 +++++++ test | 0 2 files changed, 7 insertions(+) create mode 100644 test