@@ -25,7 +25,7 @@ EXTRA_OECONF:class-native = "--disable-icu-config"
EXTRA_OECONF:class-nativesdk = "--with-cross-build=${STAGING_ICU_DIR_NATIVE} --disable-icu-config"
EXTRA_OECONF:append:class-target = "${@oe.utils.conditional('SITEINFO_ENDIANNESS', 'be', ' --with-data-packaging=archive', '', d)}"
-TARGET_CXXFLAGS:append = "${@oe.utils.conditional('SITEINFO_ENDIANNESS', 'be', ' -DICU_DATA_DIR=\\""${datadir}/${BPN}/${PV}\\""', '', d)}"
+TARGET_CXXFLAGS:append = "${@oe.utils.conditional('SITEINFO_ENDIANNESS', 'be', ' -DICU_DATA_DIR=\\""${datadir}/${BPN}/${@icu_install_folder(d)}\\""', '', d)}"
ASNEEDED = ""
On big-endian systems the preprocessor define ICU_DATA_DIR is currently being set to a path ending with the ${PV} of the recipe. The PV version string has changed to a '-' separator since oe-core commit cebe8439cdc656d53355506a31a3782312bf03c5 whereas the build system installs the data files into a path ending with the dot-separated version of ICU. This causes the ICU data file to not be detected at runtime, consequently breaking any dependant applications. We therefore substitute ${PV} with the dot-separated version string of ICU, as returned from the icu_install_folder function, on the ICU_DATA_DIR define on big-endian targets. Signed-off-by: Makarios Christakis <makchrbiz@gmail.com> --- meta/recipes-support/icu/icu_76-1.bb | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)